Journal of Family & Community Medicine
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contact us Login 
 

Users Online: 48 Home Print this page Email this page Small font sizeDefault font sizeIncrease font size

 
ORIGINAL ARTICLE
Year : 2009  |  Volume : 16  |  Issue : 2  |  Page : 53-57

Assessment of ambient noise levels in the intensive care unit of a university hospital


1 Department of Internal Medicine, College of Medicine, King Faisal University, Dammam, Saudi Arabia
2 Department of Environmental Health, College of Applied Medical Sciences, King Faisal University, Dammam, Saudi Arabia

Correspondence Address:
Khaled F El-Said
Environmental Health Department, College of Applied Medical Sciences, King Faisal University, P.O. Box 2435, Dammam 31451
Saudi Arabia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


PMID: 23012191

Rights and PermissionsRights and Permissions

Background:Noise is recognized as a source of hazard to the patient's environment. Studies have also shown that it has a direct impact on mortality and morbidity as a result of sleep deprivation which affects the immunity of critically ill patients. Objectives: The aim of this study was to measure levels of environmental noise in a six- bed, open-plan general medical intensive care unit (MICU). Methods: Levels of exposure to environmental noise were assessed in the intensive care unit of King Fahad Hospital of the University (KFHU) where measurements of environmental noise were taken using calibrated sound level meter during shifts of working days and weekends. Results : Statistical analysis revealed that there were no significant differences between noise levels in the morning, evening and night shifts of working days and weekends in the ICU of KFHU (p value =0.155, 0.53 and 0.711) respectively . There was no significant difference between overall level of exposure to noise in the working days and weekends as well (p-value=0.71). However, the assessed levels of exposures to noise were still higher than stipulated international standards. Conclusion : Some sources of environmental noise, such as the use of oxygen, suction equipment or respirators are unavoidable. Nevertheless, hospital ICUs should have measures to minimize the level of exposure to noise in the ICU. Further research in this area might focus on the noise level and other modifiable environmental stress factors in the ICU that affect patients as well as the staff.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2320    
    Printed104    
    Emailed0    
    PDF Downloaded342    
    Comments [Add]    

Recommend this journal

 

Advertise | Sitemap | What's New | Feedback | Disclaimer
Journal of Family and Community Medicine | Published by Wolters Kluwer - Medknow
Online since 05th September, 2010